Abdominal Cases
   
BIOPSY-Liver multiple lesions
  • Biopsy Plan
    This case details True-Cut Biopsy on a patient with multiple liver lesions. Anterior approach planed to target one of the lesions.
  •    
  • Check Scan
    Image Check Scan Image showing Precise needle delivery
  • BIOPSY - RETROPERITONEAL MASS
  • Biopsy Plan
    9mm left para aortic lymph node in retroperitoneum at a depth of 127mm. Posterior approach planed.
  •    
  • Check Scan Image
    showing precise needle delivery in the first pass .
  •  
    BIOPSY – LIVER MASS
  • Biopsy Plan
    Lesion at the head of liver. Procedure planned with cranial angulations to avoid puncturing the diaphragm.
  •  
       
  • Check Scan Image
    Needle inserted with combination of orbital and cranial angulations precisely to the target.
  •  
    Pancreatic lesion -multi slice planning
  • Biopsy plan
    Lesion in the lower part of pancreas at depth of 88mm. Procedure planned with combination of orbital & cranio-caudal angulations The diagnosis was undertaken at Lilavati Hospital,Mumbai.
  •  
       
  • Check scan image
    Needle placed caudally ,entering in one slice & traveling precisely to the target
  •  
    BIOPSY - RETROPERITONEAL MASS
  • Biopsy Plan
    Patient with abnormal lymph adinopathy and liver SOL. Trajectory planned through the 5mm intercostal space,avoiding kidney and the vertebra.
  •  
       
  • Check Scan Image
    Check scan showing precise positioning of needle to the target
  •  
     
    PIGA Clinical Study Report
     
     
    Total time spent decreases by 24%- Click here to read more about clinical case report
     